Labs that build or modify their own tests take on validation work FDA would otherwise do. The director signs off on whether a test is ready for patients.

Reviewed November 27, 2026 by the Sound Lab Consultants laboratory compliance team

Short answer

Tests not on CMS's complexity lists are treated as high complexity (42 CFR 493.17), so LDT labs need a director under 42 CFR 493.1443. Before reporting, the lab must establish performance specifications for each LDT or modified FDA test: accuracy, precision, analytical sensitivity and specificity, reportable range and reference intervals (42 CFR 493.1253(b)(2)).

What the director must approve

  • Validation plan and acceptance criteria
  • Accuracy, precision, analytical sensitivity, specificity and interferences
  • Reportable range and reference intervals
  • Calibration and control procedures
  • Final validation summary, signed before patient reporting

Regulatory context

A federal court vacated FDA's rule regulating LDTs as medical devices in March 2025, leaving LDTs under CLIA oversight. New York still reviews LDTs for labs testing New York specimens.

Sound Lab Consultants handles LDT development and validation.

Regulations behind this page

Every requirement on this page comes from the CLIA regulations, Title 42 Code of Federal Regulations Part 493. Open any section for the official text.

RegulationWhat it covers
42 CFR § 493.17Test categorizationHow tests are categorized as moderate or high complexity
42 CFR § 493.1253Standard: Establishment and verification of performance specificationsVerifying and establishing performance specifications (incl. LDTs)
42 CFR § 493.1443Standard; Laboratory director qualificationsHigh complexity laboratory director qualifications
Full text: 42 CFR § 493.17 Test categorization

§ 493.17 Test categorization. (a) Categorization by criteria. Notices will be published in the Federal Register which list each specific test system, assay, and examination categorized by complexity. Using the seven criteria specified in this paragraph for categorizing tests of moderate or high complexity, each specific laboratory test system, assay, and examination will be graded for level of complexity by assigning scores of 1, 2, or 3 within each criteria. The score of “1” indicates the lowest level of complexity, and the score of “3” indicates the highest level. These scores will be totaled. Test systems, assays or examinations receiving scores of 12 or less will be categorized as moderate complexity, while those receiving scores above 12 will be categorized as high complexity. Note: A score of “2” will be assigned to a criteria heading when the characteristics for a particular test are intermediate between the descriptions listed for scores of “1” and “3.” (1) Knowledge —(i) Score 1. (A) Minimal scientific and technical knowledge is required to perform the test; and (B) Knowledge required to perform the test may be obtained through on-the-job instruction. (ii) Score 3. Specialized scientific and technical knowledge is essential to perform preanalytic, analytic or postanalytic phases of the testing. (2) Training and experience —(i) Score 1. (A) Minimal training is required for preanalytic, analytic and postanalytic phases of the testing process; and (B) Limited experience is required to perform the test. (ii) Score 3. (A) Specialized training is essential to perform the preanalytic, analytic or postanalytic testing process; or (B) Substantial experience may be necessary for analytic test performance. (3) Reagents and materials preparation —(i) Score 1. (A) Reagents and materials are generally stable and reliable; and (B) Reagents and materials are prepackaged, or premeasured, or require no special handling, precautions or storage conditions. (ii) Score 3. (A) Reagents and materials may be labile and may require special handling to assure reliability; or (B) Reagents and materials preparation may include manual steps such as gravimetric or volumetric measurements. (4) Characteristics of operational steps —(i) Score 1. Operational steps are either automatically executed (such as pipetting, temperature monitoring, or timing of steps), or are easily controlled. (ii) Score 3. Operational steps in the testing process require close monitoring or control, and may require special specimen preparation, precise temperature control or timing of procedural steps, accurate pipetting, or extensive calculations. (5) Calibration, quality control, and proficiency testing materials —(i) Score 1. (A) Calibration materials are stable and readily available; (B) Quality control materials are stable and readily available; and (C) External proficiency testing materials, when available, are stable. (ii) Score 3. (A) Calibration materials, if available, may be labile; (B) Quality control materials may be labile, or not available; or (C) External proficiency testing materials, if available, may be labile. (6) Test system troubleshooting and equipment maintenance —(i) Score 1. (A) Test system troubleshooting is automatic or self-correcting, or clearly described or requires minimal judgment; and (B) Equipment maintenance is provided by the manufacturer, is seldom needed, or can easily be performed. (ii) Score 3. (A) Troubleshooting is not automatic and requires decision-making and direct intervention to resolve most problems; or (B) Maintenance requires special knowledge, skills, and abilities. (7) Interpretation and judgment —(i) Score 1. (A) Minimal interpretation and judgment are required to perform preanalytic, analytic and postanalytic processes; and (B) Resolution of problems requires limited independent interpretation and judgment; and (ii) Score 3. (A) Extensive independent interpretation and judgment are required to perform the preanalytic, analytic or postanalytic processes; and (B) Resolution of problems requires extensive interpretation and judgment. (b) Revisions to the criteria for categorization. The Clinical Laboratory Improvement Advisory Committee, as defined in subpart T of this part, will conduct reviews upon request of HHS and recommend to HHS revisions to the criteria for categorization of tests. (c) Process for device/test categorization utilizing the scoring system under § 493.17(a). (1)(i) For new commercial test systems, assays, or examinations, the manufacturer, as part of its 510(k) and PMA application to FDA, will submit supporting data for device/test categorization. FDA will determine the complexity category, notify the manufacturers directly, and will simultaneously inform both CMS and CDC of the device/test category. FDA will consult with CDC concerning test categorization in the following three situations: (A) When categorizing previously uncategorized new technology; (B) When FDA determines it to be necessary in cases involving a request for a change in categorization; and (C) If a manufacturer requests review of a categorization decision by FDA in accordance with 21 CFR 10.75. (ii) Test categorization will be effective as of the notification to the applicant. (2) For test systems, assays, or examinations not commercially available, a laboratory or professional group may submit a written request for categorization to PHS. These requests will be forwarded to CDC for evaluation; CDC will determine complexity category and notify the applicant, CMS, and FDA of the categorization decision. In the case of request for a change of category or for previously uncategorized new technology, PHS will receive the request application and forward it to CDC for categorization. (3) A request for recategorization will be accepted for review if it is based on new information not previously submitted in a request for categorization or recategorization by the same applicant and will not be considered more frequently than once per year. (4) If a laboratory test system, assay or examination does not appear on the lists of tests in the Federal Register notices, it is considered to be a test of high complexity until PHS, upon request, reviews the matter and notifies the applicant of its decision. Test categorization is effective as of the notification to the applicant. (5) PHS will publish revisions periodically to the list of moderate and high complexity tests in the Federal Register in a notice with opportunity for comment. [57 FR 7139, Feb. 28, 1992, as amended at 58 FR 5222, Jan. 19, 1993]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

Full text: 42 CFR § 493.1253 Standard: Establishment and verification of performance specifications

§ 493.1253 Standard: Establishment and verification of performance specifications. (a) Applicability. Laboratories are not required to verify or establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1) Verification of performance specifications. Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for the test system. (ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. (2) Establishment of performance specifications. Each laboratory that modifies an FDA-cleared or approved test system, or introduces a test system not subject to FDA clearance or approval (including methods developed in-house and standardized methods such as text book procedures), or uses a test system in which performance specifications are not provided by the manufacturer must, before reporting patient test results, establish for each test system the performance specifications for the following performance characteristics, as applicable: (i) Accuracy. (ii) Precision. (iii) Analytical sensitivity. (iv) Analytical specificity to include interfering substances. (v) Reportable range of test results for the test system. (vi) Reference intervals (normal values). (vii) Any other performance characteristic required for test performance. (3) Determination of calibration and control procedures. The laboratory must determine the test system's calibration procedures and control procedures based upon the performance specifications verified or established under paragraph (b)(1) or (b)(2) of this section. (c) Documentation. The laboratory must document all activities specified in this section. [68 FR 3703, Jan. 24, 2003; 68 FR 50724, Aug. 22, 2003]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

Full text: 42 CFR § 493.1443 Standard; Laboratory director qualifications

§ 493.1443 Standard; Laboratory director qualifications. The laboratory director must be qualified to manage and direct the laboratory personnel and performance of high complexity tests and must be eligible to be an operator of a laboratory within the requirements of subpart R. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if such licensing is required; and (b) The laboratory director must— (1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology; or (2)(i) Be a doctor of medicine, a doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located; and (ii) Have at least 2 years of experience directing or supervising high complexity testing; and (iii) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1445; or (3)(i)(A) Hold an earned doctoral degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B) Hold an earned doctoral degree; and ( 1 ) Have at least 16 semester hours of doctoral level coursework in biology, chemistry, medical technology (MT), clinical laboratory science (CLS), or medical laboratory science (MLS); or ( 2 ) An approved thesis or research project in biology/chemistry/MT/CLS/MLS related to laboratory testing for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings; and (ii) Be certified and continue to be certified by a board approved by HHS; and (iii) Have at least 2 years of: (A) Laboratory training or experience, or both: and (B) Laboratory experience directing or supervising high complexity testing; and (iv) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1445; or (4) Notwithstanding any other provision of this section, an individual is considered qualified as a laboratory director of high complexity testing under this section if they were qualified and serving as a laboratory director of high complexity testing in a CLIA-certified laboratory as of December 28, 2024, and have done so continuously since December 28, 2024. (5) For the subspecialty of oral pathology, be certified by the American Board of Oral Pathology, American Board of Pathology, or the American Osteopathic Board of Pathology. [57 FR 7172, Feb. 28, 1992, as amended at 58 FR 5234, Jan. 19, 1993; 59 FR 62609, Dec. 6, 1994; 62 FR 25858, May 12, 1997; 63 FR 55034, Oct. 14, 1998; 65 FR 82944, Dec. 29, 2000; 68 FR 3713, Jan. 24, 2003; 88 FR 90041, Dec. 28, 2023]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

FAQ

Common questions

Is every LDT high complexity?

Tests not categorized by FDA or CMS are high complexity under 42 CFR 493.17 until categorized.

Can a moderate complexity lab run an LDT?

Not without high complexity certification, since uncategorized tests are high complexity.

Who signs the validation?

The laboratory director (or a qualified technical supervisor under the director's responsibility).

Get a laboratory director

Tell us about your lab

Send the form and a Sound Lab Consultants team member replies within one business day with director options for your state, test menu and complexity.

Request a lab director

No obligation. Your details go only to Sound Lab Consultants.

Prefer to talk now? Call (602) 874-1311.

✓

Thank you. We have your request.

A Sound Lab Consultants team member will reply within one business day. To skip the wait, book a call now

Need a qualified laboratory director?

Sound Lab Consultants provides CLIA laboratory directors for waived, PPM, moderate and high complexity labs in all 50 states.